Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Clin Exp Optom ; 107(1): 66-74, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37082792

RESUMO

CLINICAL RELEVANCE: Traditionally, refraction is performed, and spectacles are manufactured in in 0.25D-steps. Trial and spectacle lenses manufactured in smaller increments may allow for a more accurate refraction and prescribed spectacles. BACKGROUND: To determine whether refraction in 0.05D-steps improves the proportion of eyes achieving achieve duochrome equality, and whether spectacles prescribed in 0.05D-steps offer any vision benefits, compared to 0.25D-steps. METHODS: Myopic young adults were enrolled into two prospective studies conducted at different sites. Study 1 comprised 66 participants (refracted under cycloplegia) while Study 2 comprised 51 participants (not cyclopleged). A standard refraction was performed in both studies and a trial frame and trial lenses were used to determine the spherical endpoint of duochrome equality (0.25D-steps first then 0.05D-steps). In Study 2, the cylindrical component was refined in 0.05D-steps before the spherical endpoint in 0.05D-steps. Monocular high-contrast-visual-acuity (HCVA) was measured while wearing the final refractions. Participants in Study 2 wore spectacles manufactured in 0.25D and 0.05D-steps for 7 days each in a randomized, double-masked study. Both spectacles appeared identical. Outcome measures assessed on dispensing and after 7 days of wear comprised monocular acuity-based measurements (HCVA, low-contrast-visual-acuity, vanishing-optotype-acuity, contrast-sensitivity) and subjective ratings. The Quality-of-Vision questionnaire and subjective preference were assessed after 7 days. RESULTS: Both studies showed a higher proportion of eyes achieved duochrome equality (P < 0.001) and better average monocular HCVA (P ≤ 0.006) in 0.05D-steps. Study 2 showed 0.05D-step spectacles provided better average results for all monocular acuity-based measurements (P < 0.006) and were preferred by 65% (P = 0.04) of participants after 7 days (P = 0.04). There were no differences between spectacles for any other measures (P > 0.1). CONCLUSIONS: Refraction performed, and spectacles manufactured in 0.05D-steps for this study improved average acuity-based outcomes and were preferred by most participants to spectacles in traditional 0.25D-steps.


Assuntos
Erros de Refração , Humanos , Adulto Jovem , Óculos , Estudos Prospectivos , Refração Ocular , Erros de Refração/terapia , Transtornos da Visão , Acuidade Visual , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
Ophthalmic Physiol Opt ; 43(3): 418-425, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36722376

RESUMO

INTRODUCTION: Myopia control (MC) studies in children link efficacy with subjective performance. There is little MC research in teenagers and young adults. This study compared subjective experience of MC contact lenses in different age groups. METHODS: Data were retrospectively reviewed from two double-masked, bilateral wear, crossover contact lens clinical trials (myopia -0.75D to -3.50D and <1.00 DC; 9-35 years). Participants wore two novel lenses (MC lenses with relative peripheral plus [+1.50D and +2.50D]) and a single-vision (SV) control lens (Clariti® 1 day) for 1 week each. All lenses were made from Somofilcon A material. Data collected included visual acuity (VA), wearing time, subjective ratings of comfort, distance and near vision clarity and overall vision. Generalised estimating equations with subject random intercepts and identity link functions were used in the analysis. RESULTS: A total of 31 participants (10 children, 11 teenagers and 10 adults) were included, with no difference between the age groups for VA with the dispensed lenses (p > 0.05). All groups could discriminate between the SV and MC lenses for vision (distance, near and overall) after 1 week (p < 0.05). There was no difference between groups for comfort or distance and near vision. Children rated the overall vision quality higher than teenagers and adults for both SV and MC lenses (p < 0.05), but there was no difference relative to the SV lens between groups (p > 0.50). Daily wear time was lowest for children for all lens types (all p < 0.02). Wear time was positively associated with ratings of overall vision quality for children and young adults (both p < 0.05). CONCLUSION: All age groups rated SV lenses higher than MC lenses. Subjective ratings of MC lenses appear similar between age groups relative to SV lenses. Wear time was lowest in children and was correlated with overall vision quality ratings in children and young adults.


Assuntos
Lentes de Contato Hidrofílicas , Miopia , Humanos , Adolescente , Criança , Adulto Jovem , Estudos Retrospectivos , Miopia/terapia , Acuidade Visual , Visão Ocular
3.
Eye Contact Lens ; 49(2): 63-70, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36282205

RESUMO

OBJECTIVES: The objective of this study was to compare the visual performance and binocular/accommodative function of two novel S.T.O.P. design (F2 and DT) contact lenses against MiSight when worn by myopic, young adults. METHOD: This was a prospective, randomized, cross-over, single-masked study. Each lens was worn daily wear with overnight peroxide disinfection for approximately 7 days. Visual performance was assessed with subjective ratings (0-100): clarity of vision and lack of ghosting (far away, intermediate, and near), vision when driving, overall vision satisfaction, and with monocular high-contrast and low-contrast visual acuity (HCVA/LCVA) at 6 m, binocular HCVA (6 m, 70 cm, 50 cm, and 40 cm), binocular LCVA (6 m and 70 cm). Binocular function was assessed with heterophorias (3 m and 40 cm). Accommodative function was assessed with monocular accommodative facility (AF: 40 cm) and dynamic monocular accommodative response (AR: 6 m, 70 cm, and 40 cm). RESULTS: F2 was rated higher than MiSight for clarity of vision (near and intermediate) and lack-of-ghosting ( P <0.001), while MiSight was rated higher than DT for clarity of vision (near, P <0.001). MiSight was better than F2 and DT for monocular HCVA (6 m) and binocular HCVA (6 m and 40 cm, P ≤0.02), but the maximum difference was ≤2 letters. There were no differences between designs for heterophoria ( P =0.61) nor were there any differences between DT and MiSight for any accommodative measure ( P >0.1). F2 was higher for monocular-AF ( P =0.007) and lower for AR (70 cm and 40 cm; P ≤0.007) compared with MiSight. CONCLUSIONS: The visual performance and binocular/accommodative function of S.T.O.P. designs F2 and DT were comparable with MiSight. F2 outperformed MiSight in some aspects of subjective visual performance and monocular accommodative function.


Assuntos
Lentes de Contato Hidrofílicas , Presbiopia , Adulto Jovem , Humanos , Acuidade Visual , Estudos Prospectivos , Acomodação Ocular , Visão Binocular/fisiologia
4.
Optom Vis Sci ; 98(10): 1160-1168, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34678836

RESUMO

SIGNIFICANCE: These data demonstrate that binocular vision disorders (BVDs) contribute to contact lens (CL) dissatisfaction independently of CL discomfort (CLD) in myopic, pre-presbyopic, adult, single-vision CL wearers. PURPOSE: This study aimed to determine whether BVDs contribute to CL dissatisfaction and whether this contribution is independent of CLD. METHODS: Participants attended one clinical visit while wearing their habitual CLs. Symptoms from CLD and BVDs were measured with the Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8) and Convergence Insufficiency Syndrome Survey (CISS), respectively. A comprehensive binocular vision (BV) assessment was performed. The Ocular Surface Disease Index (OSDI) was used to measure CL dissatisfaction from CLD and BVDs based on reported correlations between the CLDEQ-8 and the CISS with the OSDI. Participants were categorized according to their CL comfort status (CLD [≥12 on CLDEQ-8] or non-CLD [<12 on CLDEQ-8]) and BV status (BVD or non-BVD). RESULTS: Seventy-six participants completed the trial, and 19 (25%) were diagnosed with BVD. Those diagnosed with BVD scored higher than did those diagnosed with non-BVD for the OSDI (25.1 ± 12.7 vs. 10.7 ± 7.3, P < .001) and CISS (18.7 ± 7.7 vs. 11.9 ± 5.9, P = .001), but not the CLDEQ-8 (P = .25). Those categorized as having CLD scored higher than did those categorized as having non-CLD for the OSDI (19.0 ± 12.3 vs. 9.3 ± 5.9, P = .003) and CISS (16.1 ± 6.8 vs. 11.0 ± 6.2, P = .001). There were no significant interactions between BV status and CL comfort status for any questionnaire (P > .08). CONCLUSIONS: Higher scores for OSDI in those with CLD or BVD indicate that both conditions contribute to CL dissatisfaction. Higher scores for the CISS in those with CLD suggest a degree of overlap for some BVD symptoms. Nonsignificant differences between BVD and non-BVD for the CLDEQ-8 suggest that BVDs contribute to CL dissatisfaction independently of CLD.


Assuntos
Lentes de Contato Hidrofílicas , Síndromes do Olho Seco , Adulto , Humanos , Inquéritos e Questionários , Transtornos da Visão , Visão Binocular
5.
Eye Contact Lens ; 47(5): 271-276, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33009260

RESUMO

OBJECTIVE: Understand relationship between vision and comfort in contact lens (CL) wear. METHODS: Retrospective analysis of five trials using similar protocols with nonpresbyopic (NP) myopes or presbyopic participants (Px) wearing various simultaneous-image designs (SM) and single-vision (SV) CL (NP only). Questionnaires (vision satisfaction, vision clarity: distance/intermediate/near, comfort) on 1 to 10 scale were administered 1 week after fitting. Vision/comfort relationship was analyzed using linear mixed model and presented as regression coefficient with 95% confidence intervals (CIs). RESULTS: Vision ratings correlated with comfort ratings, although this varied depending on type of vision rating and Px category. Vision satisfaction influenced comfort for the NP-SV group (slope: 0.8; 95% CI: 0.58-1.01, P≤0.001), but was significantly lower in the presbyopic group (slope: 0.38; 95% CI: 0.33-0.42; P≤0.001). Controlling for lens material obtained similar results. In the reverse relationship, comfort had a significant impact on vision satisfaction, although again at varying levels for each Px group. NP-SV demonstrated the weakest relationship (slope: 0.47; 95% CI: 0.35-0.59, P≤0.001) in comparison to NP-SM and P-SM groups. CONCLUSION: Vision and comfort in CL wear are inter-related. Consideration of Px characteristics, visual stimulus, and CL comfort needs to be accounted for when assessing overall CL experience.


Assuntos
Lentes de Contato Hidrofílicas , Lentes de Contato , Miopia , Humanos , Satisfação do Paciente , Estudos Retrospectivos , Visão Ocular
7.
Ophthalmic Physiol Opt ; 39(4): 294-307, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31180155

RESUMO

PURPOSE: We aimed to determine myopia control efficacy with novel contact lenses (CL) that (1) reduced both central and peripheral defocus, and (2) provided extended depth of focus with better global retinal image quality for points on, and anterior to, the retina and degraded for points posterior to the retina. METHODS: Children (n = 508, 8-13 years) with cycloplegic spherical equivalent (SE) -0.75 to -3.50D were enrolled in a prospective, double blind trial and randomised to one of five groups: (1) single vision, silicone hydrogel (SH) CL; (2) two groups wearing SH CL that imposed myopic defocus across peripheral and central retina (test CL I and II; +1.00D centrally and +2.50 and +1.50 for CL I and II at 3 mm semi-chord respectively); and (3) two groups wearing extended depth of focus (EDOF) hydrogel CL incorporating higher order aberrations to modulate retinal image quality (test CL III and IV; extended depth of focus of up to +1.75D and +2.50D respectively). Cycloplegic autorefraction and axial length (AL) measurements were conducted at six monthly intervals. Compliance to lens wear was assessed with a diary and collected at each visit. Additionally, subjective responses to various aspects of lens wear were assessed. The trial commenced in February 2014 and was terminated in January 2017 due to site closure. Myopia progression over time between groups was compared using linear mixed models and where needed post hoc analysis with Bonferroni corrections conducted. RESULTS: Myopia progressed with control CL -1.12 ± 0.51D/0.58 ± 0.27 mm for SE/AL at 24 months. In comparison, all test CL had reduced progression with SE/AL ranging from -0.78D to -0.87D/0.41-0.46 mm at 24 months (AL: p < 0.05 for all test CL; SE p < 0.05 for test CL III and IV) and represented a reduction in axial length elongation of about 22% to 32% and reduction in spherical equivalent of 24% to 32%. With test CL, a greater slowing ranging from 26% to 43% was observed in compliant wearers (≥6 days per week; Control CL: -0.64D/0.30 mm and -1.14D/0.58 mm vs test CL: -0.42D to -0.47D/0.12-0.18 mm and -0.70 to -0.81D/0.19-0.25 mm at 12 and 24 months respectively). CONCLUSIONS: Contact lenses that either imposed myopic defocus at the retina or modulated retinal image quality resulted in a slower progression of myopia with greater efficacy seen in compliant wearers. Importantly, there was no difference in the myopia control provided by either of these strategies.


Assuntos
Lentes de Contato Hidrofílicas , Miopia Degenerativa/terapia , Adolescente , Análise de Variância , Criança , Método Duplo-Cego , Feminino , Humanos , Masculino , Miopia Degenerativa/prevenção & controle , Estudos Prospectivos , Desenho de Prótese
8.
Optom Vis Sci ; 96(4): 283-290, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30907859

RESUMO

SIGNIFICANCE: This study reports that subjective vision ratings are better indicators of willingness to purchase simultaneous-image contact lenses than visual acuities and are more valuable in evaluating contact lens performance. PURPOSE: The purpose of this study was to investigate the relationship between visual acuities, subjective vision ratings, and willingness to purchase simultaneous-image contact lenses in presbyopes. METHODS: A retrospective analysis of visual acuities, subjective vision ratings, and willingness to purchase from final visits of two masked, crossover clinical trials of nine prototype and four commercially available simultaneous-image contact lenses in 141 presbyopes was performed. Pearson correlation and area under the receiver operating characteristic curve determined correlations between variables. RESULTS: Most subjective vision ratings were weakly correlated (r < 0.3) with visual acuity at all distances and illumination. Moderate correlations (r, 95% confidence intervals) were found between overall vision satisfaction ratings with visual acuity at 40 (-0.34, -0.28 to -0.40) and 50 cm (-0.33, -0.27 to -0.39), near-vision ratings (daytime) with visual acuity at 40 (-0.48, -0.43 to -0.53) and 50 cm (-0.46; -0.41 to -0.51), and intermediate-vision ratings (daytime) with visual acuity at 40 (-0.39, -0.33 to -0.45) and 50 cm (-0.41, -0.35 to -0.46). Highest discrimination for willingness to purchase was with overall vision satisfaction (area under curve, 0.93) and vision stability (daytime; area under curve, 0.77). Ratings from 4 to 9 for vision satisfaction showed a linear increase in willingness to purchase: a 1-unit increase in vision satisfaction increased willingness to purchase by 20%. Ratings lower than 4 had 0% willingness to purchase. Other subjective ratings showed similar relationships, albeit only 10 to 15% increase in willingness to purchase per unit increase for ratings higher than 4. CONCLUSIONS: Subjective vision ratings are a better indicator of simultaneous-image contact lens performance than visual acuity. Overall vision satisfaction and vision stability are key predictors of willingness to purchase. Subjective vision ratings should be used to evaluate performance rather than visual acuity alone.


Assuntos
Lentes de Contato Hidrofílicas , Aceitação pelo Paciente de Cuidados de Saúde , Presbiopia/terapia , Visão Ocular/fisiologia , Acuidade Visual/fisiologia , Adulto , Comportamento do Consumidor , Feminino , Promoção da Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Presbiopia/psicologia , Estudos Prospectivos , Estudos Retrospectivos , Inquéritos e Questionários
9.
Eye Contact Lens ; 45(4): 260-270, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30601291

RESUMO

OBJECTIVE: To assess two prototype contact lenses (CLs) that extend depth of focus through deliberate manipulation of multiple spherical aberration terms (extended depth-of-focus [EDOF]) for visual performance, accommodative and binocular function, and objective static near refraction against a single-vision (SV) CL. METHOD: This was a prospective, randomized, cross-over, single-masked (participant) clinical trial in which 16 myopic children wore 2 prototype CLs (EDOFL/EDOFH) designed for presbyopes and a SV CL, each for one week. Measurements comprised monocular and binocular high-contrast visual acuity (HCVA: 6 m, 40 cm), binocular low-contrast visual acuity (LCVA: 6 m), contrast sensitivity (CS: 6 m), phorias (3 m, 33 cm), monocular-accommodative facility (33 cm), and objective static refraction (spherical equivalent M) at zero, -3, and -5 D vergences. Measurements were taken 10 min after lens insertion. Subjective response was assessed using take-home questionnaires comprising vision clarity (distance/intermediate/near), vision quality (haloes at night/ghosting), vision stability when moving (playing sport/using stairs), and comfort. RESULTS: Single vision was significantly better than both EDOF CLs for monocular HCVA, LCVA, and CS (6 m); vision clarity (distance), ghosting (P≤0.040), and EDOFL for binocular HCVA (6 m, P=0.047). M was significantly closer to the ideal objective static refraction at -3 and -5 D vergences (P≤0.004) with both EDOF compared with SV CLs. There were no differences between CLs for any other variable (P≥0.169). CONCLUSION: Extended depth-of-focus CLs caused minimal disruption to the accommodative and binocular system compared with SV CLs when worn by myopic children. Future EDOF designs for children should reduce the difference between SV for distance vision and vision quality while maintaining the same performance for intermediate and near.


Assuntos
Acomodação Ocular/fisiologia , Lentes de Contato , Percepção de Profundidade/fisiologia , Presbiopia/terapia , Visão Binocular/fisiologia , Acuidade Visual/fisiologia , Adolescente , Criança , Estudos Cross-Over , Desenho de Equipamento , Feminino , Humanos , Masculino , Estudos Prospectivos , Ajuste de Prótese , Método Simples-Cego
10.
Optom Vis Sci ; 95(12): 1096-1104, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30451806

RESUMO

SIGNIFICANCE: The present study highlights the differences between modern daily-disposable multifocal soft contact lenses to assist eye care practitioners in fitting presbyopic contact lens wearers. PURPOSE: The purpose of this study was to compare visual performance of three daily-disposable multifocal contact lenses. METHODS: Presbyopes (n = 72) wore 1-Day Acuvue Moist Multifocal, BioTrue ONEday for Presbyopia, and Dailies AquaComfort Plus Multifocal for 1 week in a prospective, randomized, double-blind, crossover clinical trial. After 1 week, high- and low-contrast visual acuities (HCVA, LCVA) were measured between 6 m and 40 cm and stereopsis at 40 cm. Subjective performance was assessed with 1- to 10-point rating scales for clarity, ghosting, driving vision, vision stability, ease of focusing, overall vision satisfaction, and ocular comfort. Willingness to purchase was reported with categorical responses. Linear mixed models and χ tests were used for analysis, and level of significance was set at 5%. RESULTS: BioTrue provided better HCVA and LCVA at distance than did Acuvue Moist (P ≤ .03). Subjectively, Acuvue Moist was rated lowest for distance clarity, distance ghosting, and driving vision (P ≤ .05). Acuvue Moist provided better HCVA at 70 to 40 cm and LCVA at 1 m to 40 cm than did BioTrue (P ≤ .01) and better LCVA at 1 m to 50 cm than did AquaComfort Plus (P ≤ .02). AquaComfort Plus also provided better HCVA and LCVA at 50 and 40 cm than did BioTrue (P ≤ .03). Acuvue Moist provided better stereopsis than did BioTrue (P = .02). Subjectively, BioTrue was rated lowest for near clarity (P ≤ .007) and lower than Acuvue Moist for intermediate clarity and near ghosting (P ≤ .04). No other differences were found between lenses (P > .05). CONCLUSIONS: BioTrue had better distance performance compared with near, whereas Acuvue Moist performed conversely. AquaComfort Plus performed reasonably overall.


Assuntos
Lentes de Contato Hidrofílicas , Equipamentos Descartáveis , Presbiopia/terapia , Acuidade Visual/fisiologia , Adulto , Idoso , Condução de Veículo , Sensibilidades de Contraste/fisiologia , Estudos Cross-Over , Percepção de Profundidade/fisiologia , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Presbiopia/fisiopatologia , Estudos Prospectivos , Ajuste de Prótese
11.
Clin Optom (Auckl) ; 10: 75-86, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30319298

RESUMO

PURPOSE: To compare the visual performance of soft contact lenses reported to reduce myopia progression. METHODS: In a double-blind, randomized, crossover trial, 30 non-presbyopic myopes wore MiSight™, center-distance Proclear® Multifocal (+2.00 D add), and two prototype lenses for 1 week each. High- and low-contrast visual acuities at 6 m, and 70 and 40 cm; stereopsis at 40 cm; accommodative facility at 33 cm; and horizontal phoria at 3 m and 33 cm were measured after 1 week. Subjective performance was assessed on a numeric rating scale for vision clarity, lack of ghosting, vision stability, haloes, overall vision satisfaction, and ocular comfort. Frequency of eye-strain symptoms and willingness to purchase lenses were also reported with categorical responses. Participants reported wearing times (total and visually acceptable). Linear mixed models and chi-square tests were employed in analysis with level of significance set at 5%. Theoretical optical performance of all lenses was assessed with schematic myopic model eyes (-1.00, -3.00, and -6.00 D) by comparing the slope of the edge spread function (ESF), an indicator for optical performance/resolution and the blur patch size of the line spread function, an indicator for contrast, between the lenses. RESULTS: Proclear Multifocal and MiSight provided the best distance acuities. However, the prototype lenses were rated significantly higher for many subjective variables, and there were no subjective variables where commercial lenses were rated significantly higher than the prototypes. Theoretical optical performance showed steeper slopes of the ESF and greater blur patch sizes of the LSP with commercial lenses, supporting the clinical findings of better visual acuities but reduced subjective performance. Participants wore prototypes longer and reported their vision acceptable for longer each day compared to MiSight. Both prototypes had the highest willingness-to-purchase rate. CONCLUSIONS: The prototypes were better tolerated by myopes compared to the commercial soft contact lenses currently used for slowing myopia progression.

12.
Clin Optom (Auckl) ; 10: 9-17, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30214337

RESUMO

OBJECTIVE: The study aimed to compare the visual performance of contact lenses with and without negative spherical aberration (SA) over 5 days of wear. METHODS: At baseline, 32 myopic participants (aged 18-33 years) were fitted in a randomized order with two lenses (test lens with minimal or no SA and 1-Day Acuvue Moist designed with negative SA) for 5 days (minimum 6 hours wear/day). Participants returned for a follow-up visit. This consisted of on-axis SA measurements; high- and low-contrast visual acuities at 6 m; high-contrast acuities at 70 and 40 cm; low-illumination, low-contrast acuity at 6 m; stereopsis at 40 cm; horizontal phorias at 3 m and 33 cm; and ±2.00 D monocular accommodative facility at 33 cm. Participants also rated (1-10 scale) vision quality (clarity and lack of ghosting for distance, intermediate, near, driving vision and vision stability during day- and night-time), overall vision satisfaction, ocular comfort, and willingness to purchase (yes/no response). RESULTS: 1-Day Acuvue Moist induced significantly (p<0.05) more negative SA at distance (Δ=0.078 µm) and near (Δ=0.064 µm) compared to the test lens, for a 6 mm pupil. There were no significant differences (p>0.05) in acuity, binocular vision, and all subjective metrics except vision stability between lenses where the test lens was rated to provide more stable vision (p<0.05). CONCLUSION: Contrary to expectations, incorporating negative SA in single vision soft contact lenses did not improve visual performance in non-presbyopic adult myopes.

13.
J. optom. (Internet) ; 11(1): 21-32, ene.-mar. 2018. graf, tab
Artigo em Inglês | IBECS | ID: ibc-169366

RESUMO

Purpose: To compare the visual performance of prototype contact lenses designed via deliberate manipulation of higher-order spherical aberrations to extend-depth-of-focus with two commercial multifocals, after 1 week of lens wear. Methods: In a prospective, participant-masked, cross-over, randomized, 1-week dispensing clinical-trial, 43 presbyopes [age: 42-63 years] each wore AIROPTIX Aqua multifocal (AOMF), ACUVUE OASYS for presbyopia (AOP) and extended-depth-of-focus prototypes (EDOF) appropriate to their add requirements. Measurements comprised high-contrast-visual-acuity (HCVA) at 6 m, 70 cm, 50 cm and 40 cm; low-contrast-visual-acuity (LCVA) and contrast-sensitivity (CS) at 6 m and stereopsis at 40 cm. A self-administered questionnaire on a numeric-rating-scale (1-10) assessed subjective visual performance comprising clarity-of-vision and lack-of-ghosting at various distances during day/night-viewing conditions and overall-vision-satisfaction. Results: EDOF was significantly better than AOMF and AOP for HCVA averaged across distances (p ≤ 0.038); significantly worse than AOMF for LCVA (p = 0.021) and significantly worse than AOMF for CS in medium and high add-groups (p = 0.006). None of these differences were clinically significant (≤2 letters). EDOF was significantly better than AOMF and AOP for mean stereoacuity (36 and 13 seconds-of-arc, respectively: p ≤ 0.05). For clarity-of-vision, EDOF was significantly better than AOP at all distances and AOMF at intermediate and near (p ≤ 0.028). For lackof-ghosting averaged across distances, EDOF was significantly better than AOP (p < 0.001) but not AOMF (p = 0.186). EDOF was significantly better than AOMF and AOP for overall-vision satisfaction (p ≤ 0.024). Conclusions: EDOF provides better intermediate and near vision performance than either AOMF or AOP with no difference for distance vision after 1 week of lens wear (AU)


Objetivo: Comparar el rendimiento visual de un prototipo de lentes de contacto diseñadas mediante manipulación deliberada de aberraciones esféricas de alto orden, para ampliar la profundidad de campo con dos lentes multifocales comerciales, tras una semana de uso. Métodos: En un ensayo clínico prospectivo, ciego para los participantes, transversal, aleatorizado, con uso de lentes durante una semana, 43 présbitas [Edad: 42-63 años] utilizaron lentes AIROPTIX Aqua multifocal (AOMF), ACUVUE OASYS para presbicia (AOP) y de profundidad de foco extendido (EDOF) adecuados a sus requisitos de adición. Las mediciones incluyeron agudeza visual de alto contraste (HCVA) a 6 m, 70 cm, 50 cm y 40 cm, agudeza visual de bajo contraste (LCVA), sensibilidad de contraste (CS) a 6 m, y estereopsis a 40 cm. Un cuestionario auto-administrado sobre una escala de evaluación numérica (1-10) valoró el rendimiento visual subjetivo incluyendo la nitidez de visión y la ausencia de imágenes fantasma a diversas distancias en condiciones de visión diurna/nocturna, así como la satisfacción sobre la visión general. Resultados: EDOF fue considerablemente mejor que AOMF y AOP para la media de las distancias HCVA (p ≤ 0,038); considerablemente peor que AOMF para LCVA (p = 0,021) y considerablemente peor que AOMF para CS en los grupos de adición media y elevada (p = 0,006). Ninguna de estas diferencias fueron clínicamente significativas (≤ 2 letras). EDOF fue considerablemente mejor que AOMF y AOP para la estereoagudeza media (36 y 13 segundos de arco, respectivamente: p ≤ 0,05). Para la claridad de visión, EDOF fue considerablemente mejor que AOP en todas las distancias, y AOMF para las distancias intermedia y cercana (p ≤ 0,028). Para la falta de imágenes fantasma promediada a las diferentes distancias, EDOF fue considerablemente mejor que AOP (p < 0,001) pero no así AOMF (p = 0,186). EDOF fue considerablemente mejor que AOMF y AOP en cuanto a satisfacción sobre la visión general (p ≤ 0,024). Conclusiones: EDOF aporta un mejor desempeño de visión intermedia y cercana que AOMF o AOP, sin diferencia de visión lejana tras una semana de uso de lentes de contacto multifocales (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Lentes de Contato/classificação , Lentes de Contato , Lentes de Contato de Uso Prolongado , Presbiopia/terapia , Miopia , Testes de Campo Visual/métodos , Testes de Campo Visual , Estudos Prospectivos , 28599 , Inquéritos e Questionários
14.
Optom Vis Sci ; 95(3): 256-263, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29424828

RESUMO

SIGNIFICANCE: This study shows satisfaction in contact lens (CL) wear is influenced by both comfort and vision. Eighty-six percent of participants were willing to continue with trial CL wear if satisfied with both comfort and vision, dropping to 50% if either variable was unsatisfactory and 0% if both were unsatisfactory. PURPOSE: The aim of this study was to understand the relationship between subjective ratings and satisfaction with CL wear. METHODS: This was a retrospective analysis of two daily-disposable CL trials (delefilcon A, somofilcon A) on participants 40 years or younger followed over 3 months. Subjective ratings (numerical rating scale 1 to 10, 1-point step) collected at visits following baseline (2 weeks, 1 and 3 months) included comfort (insertion, during day, end of day), vision clarity, and binary response for satisfaction with comfort and vision (yes/no). Willingness to continue with trial CL was obtained at completion. RESULTS: There was no significant association of comfort on insertion with comfort satisfaction (odds ratio [OR], 1.2; P = .30); however, comfort during day (OR, 2.1; P < .001) and end of day (OR, 3.4; P < .001) was associated with comfort satisfaction. For comfort during day ratings of at least 8/10 and end of day of at least 6/10, 90% of participants were considered satisfied. There was a 14% increase in participants satisfied with comfort for each unit increase on the numerical rating scale from ratings of 3 to 8 for comfort during day and a 20% increase from ratings of 3 to 7 for comfort end of day. The percentage of satisfied participants reached its maximum at a lower end of day rating (8/10) compared with during day (10/10). The percentage of participants satisfied with vision reached its maximum (100%) at a vision rating of 9/10. CONCLUSIONS: Satisfaction in CL wear is influenced by both comfort and vision. A higher rating for comfort during the day compared with end of day is necessary for participants to attain satisfaction.


Assuntos
Lentes de Contato Hidrofílicas , Conforto do Paciente/estatística & dados numéricos , Satisfação do Paciente/estatística & dados numéricos , Erros de Refração/terapia , Visão Ocular/fisiologia , Adolescente , Adulto , Equipamentos Descartáveis , Feminino , Humanos , Masculino , Razão de Chances , Erros de Refração/fisiopatologia , Estudos Retrospectivos , Acuidade Visual/fisiologia , Adulto Jovem
15.
Eye Contact Lens ; 44 Suppl 2: S157-S163, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29023311

RESUMO

OBJECTIVES: To compare visual performance of extended depth-of-focus (EDOF) prototypes with a new, center-near, commercial, multifocal contact lens. METHODS: Presbyopic participants (n=57) wore 1-Day ACUVUE MOIST MULTIFOCAL (1DAMM) and an EDOF prototype for one week in a double-masked, prospective, cross-over, randomized clinical trial. Manufacturers' guide was used to select the first pair of lens to be fit based on subjective distance refraction and near addition. After one week, high- and low-contrast visual acuities were measured at distance (6 m), intermediate (70 cm) and near (50 and 40 cm), and stereopsis at 40 cm. Subjective performance was assessed on a 1 to 10 numeric rating scale for vision clarity and lack of ghosting at distance, intermediate and near, vision stability, haloes at night time, overall vision satisfaction, and ocular comfort. Linear mixed models were used for analysis and the level of significance was set at 5%. RESULTS: 1DAMM was not significantly different from EDOF for high- or low-contrast visual acuity at any distance, or for stereopsis. Subjectively, EDOF was significantly better than 1DAMM for vision clarity at intermediate (P=0.033) and near (P<0.001), overall lack of ghosting (P=0.012), vision stability (P=0.004), and overall vision satisfaction (P=0.005). For all other subjective variables, there were no differences between EDOF and 1DAMM (P>0.05). CONCLUSIONS: EDOF prototype lenses offer improvements over the newly marketed 1DAMM lenses for several subjective variables.


Assuntos
Lentes de Contato de Uso Prolongado/normas , Presbiopia/reabilitação , Adulto , Estudos Cross-Over , Percepção de Profundidade/fisiologia , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos , Visão Ocular/fisiologia , Acuidade Visual/fisiologia
16.
Eye Contact Lens ; 44(5): 308-315, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29210828

RESUMO

OBJECTIVE: To investigate whether initial assessment of contact lenses prescribed for myopia control (MC) predicts short-term visual performance. METHOD: Retrospective analysis of 43 participants in a double-masked, randomized, cross-over trial wearing at least one lens: single-vision (SV) lens (1-DAY ACUVUE MOIST) or MC lenses (MiSight or Proclear Multifocal-Distance +2.00D). Participants completed questionnaires at the fitting visit, a take-home questionnaire (THQ) 3 days after fitting and finally at the assessment visit (≥5 days after fitting). Questions comprised vision clarity and lack of ghosting (distance, intermediate, near at day/night time); vision stability; driving vision; overall vision satisfaction and comfort (1-10 scale, 1-point steps); and willingness to purchase based on vision and MC benefit of lens (yes/no response). Visual acuity was measured at fitting and assessment visits. RESULTS: Vision clarity (intermediate and near) was significantly worse at assessment compared with fitting while wearing MC lenses (P<0.001), as was overall vision satisfaction (P<0.001), comfort (P<0.001), and vision stability (P=0.001) while wearing either SV or MC lenses. Participants willing to purchase at assessment visit was 84% with SV and 36% with MC lenses, increasing to 88% (SV, P=1.00) and 61% (MC, P<0.001) if the lenses slowed myopia progression. Visual acuity was no different with either MC or SV lenses at fitting or assessment (P≥0.251). CONCLUSION: Initial performance at fitting did not predict short-term performance for SV or MC lenses. A significant increase in willingness to purchase if lenses slowed myopia progression was observed while wearing MC lenses. Educating patients on the benefits might increase acceptability of MC lenses.


Assuntos
Lentes de Contato Hidrofílicas , Miopia/terapia , Procedimentos Ortoceratológicos/métodos , Adolescente , Adulto , Estudos Cross-Over , Método Duplo-Cego , Humanos , Miopia/fisiopatologia , Aceitação pelo Paciente de Cuidados de Saúde , Satisfação do Paciente , Estudos Retrospectivos , Acuidade Visual/fisiologia , Adulto Jovem
17.
J Optom ; 11(1): 21-32, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28619486

RESUMO

PURPOSE: To compare the visual performance of prototype contact lenses designed via deliberate manipulation of higher-order spherical aberrations to extend-depth-of-focus with two commercial multifocals, after 1 week of lens wear. METHODS: In a prospective, participant-masked, cross-over, randomized, 1-week dispensing clinical-trial, 43 presbyopes [age: 42-63 years] each wore AIROPTIX Aqua multifocal (AOMF), ACUVUE OASYS for presbyopia (AOP) and extended-depth-of-focus prototypes (EDOF) appropriate to their add requirements. Measurements comprised high-contrast-visual-acuity (HCVA) at 6m, 70cm, 50cm and 40cm; low-contrast-visual-acuity (LCVA) and contrast-sensitivity (CS) at 6m and stereopsis at 40cm. A self-administered questionnaire on a numeric-rating-scale (1-10) assessed subjective visual performance comprising clarity-of-vision and lack-of-ghosting at various distances during day/night-viewing conditions and overall-vision-satisfaction. RESULTS: EDOF was significantly better than AOMF and AOP for HCVA averaged across distances (p≤0.038); significantly worse than AOMF for LCVA (p=0.021) and significantly worse than AOMF for CS in medium and high add-groups (p=0.006). None of these differences were clinically significant (≤2 letters). EDOF was significantly better than AOMF and AOP for mean stereoacuity (36 and 13 seconds-of-arc, respectively: p≤0.05). For clarity-of-vision, EDOF was significantly better than AOP at all distances and AOMF at intermediate and near (p≤0.028). For lack-of-ghosting averaged across distances, EDOF was significantly better than AOP (p<0.001) but not AOMF (p=0.186). EDOF was significantly better than AOMF and AOP for overall-vision-satisfaction (p≤0.024). CONCLUSIONS: EDOF provides better intermediate and near vision performance than either AOMF or AOP with no difference for distance vision after 1 week of lens wear.


Assuntos
Lentes de Contato Hidrofílicas , Percepção de Profundidade/fisiologia , Presbiopia/terapia , Acuidade Visual/fisiologia , Adulto , Sensibilidades de Contraste , Estudos Cross-Over , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Presbiopia/fisiopatologia , Estudos Prospectivos , Inquéritos e Questionários
18.
Eye Contact Lens ; 44 Suppl 1: S167-S172, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28099285

RESUMO

OBJECTIVE: To compare subjective, objective and safety performance of silicone hydrogel (SiHy) daily disposable (DD) with hydrogel (Hy) DD contact lenses. METHOD: Retrospective analysis on approximately 40 participants (Px) each in 5 trials. Lenses grouped into SiHy (delefilcon A, somofilcon A, narafilcon A) and Hy (omafilcon A, nelfilcon A). Participants attended follow-up visits at baseline, 2 weeks, 1 and 3 months. Subjective ratings (1-10 scale), adverse events (percentage of Px), physiological variables (0-4 scale), and wearing time were collected at each visit and compared between groups. RESULT: Trials enrolled 201 Px totally. No differences in age, sex, and lens wear experience were found between SiHy and Hy groups (P≥0.09). There was greater increase in limbal redness from baseline in Hy group (0.18±0.38 vs. 0.02±0.47, P<0.001), whereas conjunctival staining and indentation were less in Hy group (P<0.001). No differences in comfortable wearing time were found between groups (P=0.41), and comfort at insertion, during day, and end of day was also no different (P≥0.71). Incidence of corneal infiltrative events (SiHy vs. Hy: 6.7% vs. 2.5%; P=0.32) and mechanical adverse events (SiHy vs. Hy: 0.0% vs. 0.0%; P=1.00) were no different. CONCLUSION: Though some statistical significance was found between the groups, these differences were within measurement error. Neither material types showed superiority in comfort, and adverse event rates were low with both material types. These findings suggest that choice of material is a patient and practitioner preference; however, for patients at risk of hypoxia-related complications, SiHy materials should be considered.


Assuntos
Lentes de Contato Hidrofílicas , Doenças da Córnea/terapia , Equipamentos Descartáveis , Hidrogéis , Satisfação do Paciente , Silicones , Adulto , Doenças da Córnea/metabolismo , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Lágrimas , Fatores de Tempo
19.
Cont Lens Anterior Eye ; 40(6): 367-381, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28993069

RESUMO

PURPOSE: To describe a ranked symptoms scale (RSS) discriminating subjective responses in contact lens (CL) wear in various situations. METHOD: Forty experienced clinical trial participants were interviewed for their perceptions of ocular comfort scales, resulting in a numerical RSS. For further evaluation, 20 CL wearers enrolled into a prospective, randomised, crossover trial. Two silicone-hydrogel CLs and a lens care solution (LCS) [Combinations A & B] were selected based on prior performance identifying best/worst combinations for end-of-day comfort. The RSS and a numerical rating scale (NRS) were administered at two time-points (insertion/removal) on alternating days for 6 days. RESULTS: Both NRS and RSS showed acceptable internal consistency for comfort, vision and handling (Cronbach alpha=0.71 for both scales) and similar repeatability for comfort and handling (coefficients-of-repeatability within 0.1 and 0.2 units, respectively, for each scale). The NRS and RSS discriminated differences between combinations for comfort (p≤0.031) and vision (p≤0.026) at both time-points. Additionally, the RSS showed lens/edge awareness influenced discomfort the most, ranking higher at insertion (p=0.038) and higher for Combination-B at both time-points (p≤0.002). Symptoms of dryness and tired eyes increased for both combinations at removal (p<0.02). The RSS also showed haziness and blurred distance vision influenced vision dissatisfaction with Combination-B at lens removal (p≤0.038) while eye strain/headache increased for both combinations by time of removal (p≤0.013). CONCLUSIONS: The RSS is able to discriminate subjective responses between combinations and time-of-day. The RSS's ability to rank symptoms may be a useful tool in understanding perceptions of discomfort or dissatisfaction with CL wear.


Assuntos
Lentes de Contato , Satisfação do Paciente , Refração Ocular/fisiologia , Erros de Refração/terapia , Inquéritos e Questionários , Adulto , Idoso , Estudos Cross-Over , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Erros de Refração/fisiopatologia , Resultado do Tratamento , Adulto Jovem
20.
J. optom. (Internet) ; 10(1): 14-25, ene.-mar. 2017. tab, graf
Artigo em Inglês | IBECS | ID: ibc-159405

RESUMO

Purpose: To compare the visual performance of prototype contact lenses which extend depthof-focus (EDOF) by deliberate manipulation of multiple higher-order spherical aberration terms and a commercially-available center-near lens (AIR OPTIX Aqua Multifocal, AOMF). Methods: This was a prospective, cross-over, randomized, single-masked (participant), shortterm clinical trial where 52 participants (age 45-70 years) were stratified as low, medium or high presbyopes and wore EDOF and AOMF on different days. Objective measures comprised high and low contrast visual acuity (HCVA/LCVA, log MAR), and contrast sensitivity (log units) at 6 m; HCVA at 70 cm, 50 cm and 40 cm and stereopsis (seconds of arc) at 40 cm. HCVA at 70 cm, 50 cm and 40 cm were measured as «comfortable acuity» rather than conventional resolution acuity. Subjective measures comprised clarity-of-vision and ghosting at distance, intermediate and near, overall vision satisfaction and ocular comfort (1-10 numeric rating scale) and lens purchase (yes/no response). Statistical analysis included repeated measures ANOVA, paired t-tests and McNemar’s test. Results: Significant differences between lens types were independent of strata (p ≥ 0.119). EDOF was significantly better than AOMF for HCVA at 40 cm (0.42 ± 0.18 vs. 0.48 ± 0.22, p = 0.024), stereopsis (98 ± 88 vs. 141 ± 114, p < 0.001), clarity-of-vision at intermediate (8.5 ± 1.6 vs. 7.7 ± 1.9, p = 0.006) and near (7.3 ± 2.5 vs. 6.2 ± 2.5, p = 0.005), lack-of-ghosting (p = 0.012), overall vision satisfaction (7.5 ± 1.7 vs. 6.4 ± 2.2, p < 0.001) and ocular comfort (9.0 ± 1.0 vs. 8.3 ± 1.7, p = 0.002). Significantly more participants chose to only-purchase EDOF (33% vs. 6%, p = 0.003).). There were no significant differences between lens types for any objective measure at 6 m or clarity-of-vision at distance (p ≥ 0.356). Conclusions: EDOF provides better intermediate and near vision performance in presbyopes than AOMF with no difference for distance vision during short-term wear (AU)


Objetivo: Comparar el rendimiento visual de prototipos de lentes de contacto con las de profundidad de campo extendida (EDOF), mediante la manipulación deliberada de múltiples aberraciones esféricas de alto orden y las lentes de visión simultánea centro-cerca comercialmente disponibles (AIR OPTIX Aqua Multifocal, AOMF). Métodos: Ensayo clínico prospectivo, transversal, aleatorizado, con máscara única (participante), y a corto plazo, en el que se estratificó la presbicia de 52 participantes (de edades comprendidas entre 45 y 70 años) como baja, media o alta; dichos participantes utilizaron lentes EDOF y AOMF en días diferentes. Las mediciones objetivas incluyeron la agudeza visual de alto y bajo contraste (HCVA/LCVA, log MAR), y la sensibilidad al contraste (unidades log) a 6 m, HCVA a 70 cm, 50 cm y 40 cm, y estereopsis (segundos de arco) a 40 cm. La HCVA a 70 cm, 50 cm y 40 cm se midió como «agudeza de confort» en lugar de la agudeza de resolución convencional. Las mediciones subjetivas incluyeron la claridad de visión y la visión fantasma (ghosting) a distancia, la satisfacción con la visión general intermedia y lejana, el confort ocular (escala de clasificación numérica de 1a 10) y la adquisición de lentes de contacto (respuesta sí/no). El análisis estadístico incluyó la prueba ANOVA con medidas repetidas, la prueba de t pareada, y la prueba de McNemar. Resultados: La significación de las diferencias entre los tipos de lentes fue independiente de los estratos (p ≥ 0,119). Los resultados de EDOF fueron considerablemente mejores que los de AOMF en cuanto a HCVA a 40 cm (0,42 ± 0,18 frente a 0,48 ± 0,22, p = 0,024), estereopsis (98 ± 88 frente a 141 ± 114, p < 0,001), claridad de visión intermedia (8,5 ± 16 frente a 7,7 ± 1,9, p = 0,006) y próxima (7,3 ± 2,5 frente a 6,2 ± 2,5, p = 0,005), ausencia de visión fantasma (p = 0,012), satisfacción con la visión general (7,5 ± 1,7 frente a 6,4 ± 2,2, p < 0,001) y confort ocular (9,0 ± 1,0 frente a 8,3 ± 1,7, p = 0,002). Un número considerable de participantes optó por adquirir únicamente EDOF (33% frente al 6%, p = 0,003). No se produjeron diferencias significativas entre los dos tipos de lentes en relación a las mediciones objetivas a 6 m, ni a la claridad de visión lejana (p ≥ 0,356). Conclusiones: Las lentes EDOF proporcionaron un mejor rendimiento de la visión intermedia y próxima en pacientes con presbicia que las lentes AOMF, sin que se produjeran diferencias en cuanto a visión lejana con el uso a corto plazo (AU)


Assuntos
Humanos , Masculino , Feminino , Lentes/provisão & distribuição , Transtornos da Visão/diagnóstico , Análise de Variância , Presbiopia/metabolismo , Presbiopia/patologia , Lentes/classificação , Transtornos da Visão/complicações , Estudos Prospectivos , Presbiopia/complicações , Presbiopia/diagnóstico , Lentes de Contato
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...